All Categories
Case

Home /  Case

Back

(2019 Changsha)Changsha Xinzhengkang Tableware Disinfection and Distribution Center

微信图片_20201024103327

Machine model: 0.2Y/Q-0.7(Purchase time: 2019.3)

Number of machines: 1

Usage: Tableware cleaning and disinfection

Plan: Support the production line to clean cups, plates and dishes, heat the dishwashing water for the front production line, and deliver steam to the back production line for disinfection.

On-site situation: The date on the equipment nameplate is April 2019, the purchase time is 2019, the water source is tap water, the fuel is natural gas, and it is equipped with a water softener. The on-site water softener is useless. Use it 8 to 10 hours a day. When I arrived at the scene, I was told that one of the burners was broken and could not be used. It had been out of service for two or three months. I contacted the company's after-sales service and was waiting for them to come over. Water kept coming out of the overflow port of the economizer, the solenoid valve was broken, and the burner program control box was broken and could not be used. It was replaced on site. The solenoid valve will be notified to the after-sales department and sent to the user, and the user will be asked to replace it at that time. Master Gong has instructed the user how to replace it.

微信图片_20201024103350

Note: After the 0.2-meter equipment is used to heat the dishwashing water in the assembly line to 70 degrees, the temperature in the disinfection box is no longer enough. The user is advised to add equipment or a superheater on site (the user has asked about an 800-degree high-temperature steam generator) ), explain to the user that high temperature is achieved through a steam heater. The user is interested in the heater and wants to buy it. Some users were also told to directly add another steam equipment, but the users said that the natural gas pressure of the added equipment was not enough. The natural gas pressure of the 0.2 liter equipment at the site was a bit insufficient and the firepower was too small. The user is still interested in the heater, please contact the salesperson. (The boss mentioned that he introduced the 0.4 fuel equipment of the last station 6 Ji’an Tableware Disinfection Company)


Prev

None

ALL

(2020 Wuhan)School of Power and Mechanical Engineering, Wuhan University

Next
Recommended Products